Tripp Lite Isolator IS1800HG 6 outlets Transformer, Hospital Grade Outlets, 20A Circuit Breaker, UL/cUL Certified
Tripp Lite Isolator IS1800HG 6 outlets Transformer, Hospital Grade Outlets, 20A Circuit Breaker, UL/cUL Certified
Tripp Lite IS1800HG
- Free Shipping
- 2 Year Warranty
- 30 Day Returns
- Carbon Neutral
Product Key Features
- Complete line isolation, noise filtering and surge suppression; ideal for sensitive equipment
- 1800 watts, 6 outlets, 10-ft. power cord
- Hospital-grade plug and receptacles
- Leakage current less than 100 microamps
- Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
Tripp Lite Isolator IS1800HG 6 outlets Transformer, Hospital Grade Outlets, 20A Circuit Breaker, UL/cUL Certified
Tripp Lite IS1800HG
- Free Shipping
- 2 Year Warranty
- 30 Day Returns
- Carbon Neutral
Product Key Features
- Complete line isolation, noise filtering and surge suppression; ideal for sensitive equipment
- 1800 watts, 6 outlets, 10-ft. power cord
- Hospital-grade plug and receptacles
- Leakage current less than 100 microamps
- Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
Tripp Lite
IS1800HG
Isolator Series UL60601-1 Listed Medical Grade Isolation Transformers offer line isolation, continuous noise filtering and enhanced common mode surge suppression. An internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator medical-grade transformers ideal for protection of sensitive electronic equipment in patient-care areas. Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps. Secondary neutral-to-ground bonding virtually eliminates common mode noise, providing an isolated neutral-ground reference for sensitive equipment, and an inexpensive alternative to dedicated circuits and site electrical upgrades. Removes EMI/RFI noise, utility switching transients and harmonics generated by other on-site loads and utility or lightning related surge conditions. Additional surge suppression components placed at the line input and output combined with full line isolation offer continuous filtering of a full range of power line noise in all modes. Active transformer filtering provides continuous common-mode noise rejection with no wearable parts. Unique ability to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEE
Product Description
Prevent Power Disruptions in Medical Environments - UL60601-1 Compliant
All isolation transforms must conform to the UL 60601-1 standard when used within patient care areas. Prevent power disruptions for all sensitive devices in patient care areas and other vulnerable environments with Tripp Lite’s IS1800HG Medical-Grade Isolation Transformer and Power Conditioner. Featuring an internal isolation transformer in an all-metal housing with Faraday Shielding, the IS1800HG completely isolates equipment from line noise that can cause incremental, but devastating, equipment damage. Its 1190-joule surge suppression rating protects equipment from strong surges and spikes caused by utility power disruptions and nearby equipment operating on the same circuit. With 100% isolation from the input AC line, the IS1800HG eliminates leakage and shock potential down to less than 100 microamps. The IS1800HG’s 10-ft. power cord allows for flexibility when installing, while the built-in circuit breaker prevents dangerous circuit overloads. An 1800-watt capacity allows the IS1800HG to be used with a variety of sensitive monitoring, diagnostic and computer equipment. The 6 widely spaced 5-20R-HG hospital-grade output receptacles accommodate standard 5-20P-HG industrial-grade input plugs, and a power switch offers convenient, one-touch control. For peace of mind, the IS1800HG comes with a two-year warranty, is TAA-compliant for GSA Schedule purchases, and uses a RoHS-compliant design.
Approved for Use in Patient Care Areas
UL 60601-1 compliance is required for isolation transformers within patient care areas in order to avoid hazardous conditions and provide an optimally safe environment for patients, staff and visitors. By isolating equipment from unpredictable and disruptive utility power, the IS1800HG eliminates the need for dedicated circuits or costly upgrades to a healthcare facility’s electrical system. The internal isolation transformer with Faraday Shielding provides 100% isolation from the AC power line for equipment plugged into the IS1800HG and reduces leakage to less than 100 microamps for full UL 60601-1 compliance. The IS1800HG is perfect for protecting sensitive medical equipment that can be affected by EMI/RFI line noise, utility switching transients, background spikes and other unpredictable power conditions.
High-Capacity with Robust Power Protection
The IS1800HG’s 1800-watt capacity can handle a variety of electronic medical devices, while features like an 1190-joule surge suppression rating, integrated circuit breaker and powerful line noise filtering ensure ultimate protection and safety in even the most hazardous conditions. With continuous transformer filtering and no wearable parts, the IS1800HG reduces surges in the worst power environments to harmless levels.
Convenient, User-Friendly Operation
A 10-foot cord allows for flexible installation, while six hospital-grade NEMA 5-20R-HG output receptacles let you plug standard equipment into the IS1800HG without any adapters or custom power cords. Operation is easy; simply plug the IS1800HG into a grounded three-prong utility outlet, plug your equipment into the IS1800HG and turn the power on with simple, one-touch lighted power switch.
2-Year Warranty and Environmentally Responsible Design
The IS1800HG is backed by a 2-year warranty and is compliant with UL 60601-1, TAA, and RoHS standards.
Complete Line of Medical & Hospital Grade Products
Tripp Lite has a complete line of medical grade (full UL60601-1 Compliance) and hospital grade products, including Power Strips, Surge Protectors, UPS Systems, Isolation Transformers, Mobile-Cart Power and more. Tripp Lite medical and hospital grade products are perfect for hospital, clinic, nursing home, doctor's office, surgery centers and other healthcare facilities. Learn more at the Amazon Tripp Lite store www. amazon. com/tripplite
IS1800HG Medical-Grade Isolation Transformer
- Complete line isolation, noise filtering and surge suppression for sensitive medical equipment
- Full UL 60601-1 compliance permits use within designated patient-care areas
- Faraday Shield offers 100% isolation from the input AC line
- 1800-watt continuous capacity with 6 hospital-grade NEMA 5-20R-HG output receptacles
- 1190-joule surge suppression rating
- 10-ft. power cord with hospital-grade input plug allows for installation flexibility
- Circuit breaker provides overload protection
Return Policy |
Time to Return |
Standard Return Policy |
We offer a hassle-free 30-day returns policy for domestic (US) orders, excluding non-refundable items. Refund or Replacement within 30 days of the delivery date. All products that fall under the Standard Return Policy qualify for our 30-Day Hassle-Free Returns. Please see the section above for more details. |
Replacement Only Return Policy |
Replacement within 30 days of the delivery date. |
Manufacturer Only Return Policy |
Covered by the manufacturer's warranty. Please refer to the terms and conditions for the manufacturer's warranty or contact the manufacturer. |
Holiday Extended Return Policies |
Extended Holiday Return Policy.Qualifying purchases of products displaying the " Extended Holiday Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Refund or Replacement until January 31, 2024. Extended Holiday Replacement-Only Return PolicyQualifying purchases of products displaying the " Extended Holiday Replacement-Only Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Replacement until January 31, 2024. |