Fire-Lite Select B224RB-WH Low Power Relay Base

Fire-Lite Select B224RB-WH Low Power Relay Base
Fire-Lite Select B224RB-WH Low Power Relay Base
Fire-Lite Select B224RB-WH Low Power Relay Base
Fire-Lite Select B224RB-WH Low Power Relay Base

Fire-Lite Select B224RB-WH Low Power Relay Base

Fire-Lite B224RB-WH

$89.99
Brand New
Availability: In stock , ready to be shipped .
  • Free Shipping
  • 1 Year Warranty
  • 30 Day Returns
  • Carbon Neutral
$89.99
FREE Returns
FREE Delivery
Order in the next

hrs

mins

to be delivered on

Shipping information

-
+
Ask Our Experts
Call Us Now
888.267.9566

Fire-Lite Select B224RB-WH Low Power Relay Base

Fire-Lite B224RB-WH

$89.99
FREE Returns
Brand New
Availability: In stock , ready to be shipped .
  • Free Shipping
  • 1 Year Warranty
  • 30 Day Returns
  • Carbon Neutral
$89.99
FREE Returns
-
+
FREE Delivery
Order in the next

hrs

mins

to be delivered on

Shipping information

Ask Our Experts
Call Us Now
888.267.9566
Minimize
Info
Info Page
Reviews Top
×

×
  • Description
  • Tech Specs
  • Refund Policy

Fire-Lite

B224RB-WH

To meet local code and application requirements,
System Sensor offers standard 4" and 6" bases, as well as, specialty base designs including relay, isolator, sounder and low frequency sounder options for Select Series detectors.
The standard 4" and 6" bases offer a plug-in detector base intended for use in intelligent systems, with screw terminals provided for power (+ and -), and remote annunciator connections. Communication takes place over the power (+ and -) lines. The 4" base offers a compact design while the 6" base provides compatibility with a wider range of junction boxes.
The Select Series specialty bases support application driven requirements. The bases employ a separate mounting plate that installs on various junction box sizes to eliminate unsightly surface-mount boxes. The mounting plate enables pre-wiring of all connections to speed and simplify installation.
Relay bases (B224RB-WH/B224RB-IV) provide one form C contact relay for control of auxiliary functions, such as door closure and elevator recall. The relay can operate in two different modes (short and long delay). The activation time for the short delay is 60 ms to 100 ms, while the activation time for the long delay is 6 sec to 10 sec. A shunt with pin headers, located on the base PC board, is used to set the delay timing.
Isolator bases (B224BI-WH/B224BI-IV) allow the Signaling Line Circuit (SLC) loop to operate under fault conditions created from a short circuit preventing an entire communication loop from being disabled. The base isolates the section of the loop containing the short circuit from the remainder of the circuit and automatically restores when the fault is corrected.
The Select Series sounder and low frequency sounder bases are designed for new and existing dwelling unit applications. They offer maximum flexibility in installation, configuration, and operation to meet or exceed UL 268 and UL 464 requirements. The Select Series low frequency sounder bases are designed to meet the NFPA 72 sleeping space requirement to produce a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent. Studies show that a lower frequency, centered around 520 Hz, is the most ideal to wake sleeping occupants, even those with mild to severe hearing loss. The B200SR sounder and LF sounder bases (B200SR-WH/B200SR-IV/B200SR-LF-WH/B200SR-LF-IV) are fully compatible with existing B501BH-Series sounder base installations. The device enables users to select one of two B501-supported tones (ANSI Temporal 3 or Continuous) through a jumper.
The B200S sounder and LF sounder bases (B200S-WH/B200S-IV/B200S-LF-WH/B200S-LF-IV) adopt the same address as the detector, but use a unique device type on the loop. The Fire Alarm Control Panel (FACP) can use that address to command an individual sounder - or a group of sounders - to activate. The command set from the FACP can be tailored to multiple event-driven tone outputs allowing selection of volume (75 or 85 dBA), tone (ANSI Temporal 3, ANSI Temporal 4 or March Time) and group. In addition, some FACPs will enable custom tone patterns. The B200S series sounder bases recognize the System Sensor synchronization protocol. This enables it to be used as a component of the general evacuation signal - along with other System Sensor AV appliances - when connected to a power supply or FACP output capable of generating the System Sensor synchronization pulses.

Return Policy

Time to Return

Standard Return Policy

We offer a hassle-free 30-day returns policy for domestic (US) orders, excluding non-refundable items. Refund or Replacement within 30 days of the delivery date. All products that fall under the Standard Return Policy qualify for our 30-Day Hassle-Free Returns. Please see the section above for more details.

Replacement Only Return Policy

Replacement within 30 days of the delivery date.

Manufacturer Only Return Policy

Covered by the manufacturer's warranty. Please refer to the terms and conditions for the manufacturer's warranty or contact the manufacturer.

Holiday Extended Return Policies

Extended Holiday Return Policy.

Qualifying purchases of products displaying the " Extended Holiday Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Refund or Replacement until January 31, 2024.


Extended Holiday Replacement-Only Return Policy

Qualifying purchases of products displaying the " Extended Holiday Replacement-Only Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Replacement until January 31, 2024.

FAQ

Related searches

Recently Viewed Products